Addressable Fire System
Showing 17–25 of 25 resultsSorted by popularity
-
Smoke Detectors, Addressable Fire System, Fire Detection System, Heat Detector
Menvier Intelligent Addressable Sensor Bases
Quick View
Smoke Detectors, Addressable Fire System, Fire Detection System, Heat DetectorMenvier Intelligent Addressable Sensor Bases
Menvier Intelligent Addressable Sensor Bases
- Sensor shorting link
- Separate loop in and loop out terminals
- Stand off fixing feature
- Accepts side entry cables
- Selectable sensor locking feature
SKU: n/a -
Fire Panel, Addressable Fire System, Fire Detection System
Menvier Touch-screen Repeater Panel
Quick View
Fire Panel, Addressable Fire System, Fire Detection SystemMenvier Touch-screen Repeater Panel
Menvier Touch-screen Repeater Panel
- Plug and play. All information is downloaded through the network
- Touch-screen display
- Integrated network capability allows networking with the latest Menvier range of
- intelligent addressable fire alarm control panels
- Multi language capability
- Up to 126 repeaters can be connected to the network
- Programmable as an active or passive repeater
SKU: n/a -
Fire Panel, Addressable Fire System, Fire Detection System
Menvier Df6100 Range Intelligent Addressable Control Panel
Quick View
Fire Panel, Addressable Fire System, Fire Detection SystemMenvier Df6100 Range Intelligent Addressable Control Panel
Menvier Df6100 Range Intelligent Addressable Control Panel
- Large versatile touch screen display
- Competitive single or two loop system
- Spur tolerant soft addressing
- Large selection of compatible ancillaries
- Full network capability
- Integral battery and power supply
- 200 address capacity per loop
- Approved to EN54 Pt13 and EN54 Pt2 and Pt4
SKU: n/a -
Fire Panel, Addressable Fire System, Fire Detection System
C-Tec CFP Two Wire 2 Zone AlarmSense Control Panel
Quick View
Fire Panel, Addressable Fire System, Fire Detection SystemC-Tec CFP Two Wire 2 Zone AlarmSense Control Panel
C-Tec CFP Two Wire 2 Zone AlarmSense Control Panel
- LPCB certified to EN54 parts 2 and 4
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry to access level 2
- 2, 4 or 8 AlarmSense zone circuits (dependent on model purchased)
- Four conventional sounder circuits
- Integral 1.5A EN54-4/A2 compliant switch mode PSU
- Wide range of engineering functions including zone test, coincidence, zone delay and non- latching zones
- Two on-board relays (Fire and Fault)
- Two open-collector outputs (Remote and Reset)
- ‘Class change’ and alert inputs
- Installer-friendly design accommodates easy first fix and straightforward maintenance
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required
- Low quiescent current
- Multiple indicators
- End of line units included (one per zone)
- Ancillary system expansion connections provided for up to eight two-wire repeaters (one CFP761 network driver card required per system) and optional CFP relay boards
- Space for two x 12V 3.3Ah VRLA batteries.
SKU: n/a -
Smoke Detectors, Addressable Fire System, Fire Detection System
C-Tec Addressable Smoke Detectors
Quick View
Smoke Detectors, Addressable Fire System, Fire Detection SystemC-Tec Addressable Smoke Detectors
C-Tec Addressable Smoke Detectors
- Addressable Technology:Â These smoke detectors are equipped with addressable technology, allowing them to be individually identified and controlled within a fire detection system.
- Photoelectric Sensing:Â Many C-TEC addressable smoke detectors use photoelectric sensing technology, which is highly effective at detecting smoldering fires and the presence of smoke particles.
- Advanced Algorithms:Â They often feature advanced algorithms that can differentiate between genuine fire conditions and non-fire events, reducing the likelihood of false alarms.
- Built-In Sounders:Â Some models include built-in sounders that provide audible alerts locally at the detector, increasing the chances of early detection by occupants.
- Remote Monitoring:Â Addressable technology enables remote monitoring and control of the detectors, allowing for quick response and system management.
- Tamper Resistance:Â C-TEC addressable smoke detectors are designed to be tamper-resistant to prevent unauthorized interference or deactivation.
- Multiple Power Options:Â They can operate on various power inputs, including low voltage and mains power, offering flexibility in installation.
SKU: n/a -
Heat Detector, Addressable Fire System, Fire Detection System
C-Tec Addressable Heat Detector
Quick View
Heat Detector, Addressable Fire System, Fire Detection SystemC-Tec Addressable Heat Detector
C-Tec Addressable Heat Detector
- A high quality programmable heat detector for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
- LPCB certified to EN54-5 & 17 and Kiwa Telefication certified to EN54-13.
- Can be programmed to operate as a Class A1R (rate of rise), Class A2 (64ºC fixed temperature) or Class B (76ºC fixed temperature) heat detector. Default setting is A2.
- Onboard short circuit loop isolator.
- Includes two 8mm x 2mm ultra-bright red LED indicating strips.
- Different sensitivities can be selected for different times of the day (day/night, building occupied/unoccupied etc).
- 5mA typical alarm current (370uA typical quiescent) @ 22-40V DC.
- Programmable multi-function status LED.
- Compatible with C-TEC’s CA408 CAST base c/w integrated locking mechanism & ID tag.
SKU: n/a