Asenware 2 Zone Fire Alarm Control Panel
  • It has 2 level control mode by a lock
  • It has a SILENCE button to stop BUZZER and SOUNDERS.
  • It has EVACUATE button to start a manual fire alarm immediately.
  • It has an optional GSM module for fire alarm by SMS.

Compare
Asenware 2 Zone Fire Alarm Control Panel

The AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard

And it is the central part of conventional fire alarm system, designed for applications requiring smoke detector, bell, manual pull stations, and sprinkler supervision.

Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.

AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
It is modularized design, the panel can extend from 1 zone to 32 zones easily.
It has 2 level control mode by a lock
It has a SILENCE button to stop BUZZER and SOUNDERS.
It has EVACUATE button to start a manual fire alarm immediately.
It has a battery low protection function when the battery voltage lower than 21VDC, the battery will be cut off automatically until the mains power is on.
It has an optional GSM module for fire alarm by SMS.
It is economic, user-friendly and easy maintenance.

Product Features

1. AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
2. It is modularized design, the panel can expand from 1 zone to 32 zones easily.
3. It has 2 level control mode by a lock.
4. It has 24VDC power supply output.
5. It has FIRE and FAULT signal output.
6. It has 2 general sounders output.
7. Each zone has 1 circuit detectors input.
8. Each zone can be disable by a button.
9. It has RESET button to reset the panel.
10. It has SILENCE button to stop BUZZER and SOUNDERS.
11. It has EVACUATE button to start a manual fire alarm immediately.
12. It has an optional GSM module for fire alarm by SMS.
13. It is economic, user-friendly and easy maintenance.

Mains supply voltage 110VAC or 220VAC
Internal power supply 27.2VDC
Total output current limited 500mA @ 240VAC
Batteries (default configuration) 12V2.3AH*2
Number of circuit 2
End of Line device 6.8k Ω,5% tolerance, 0.5-1W (colour code-blue,grey,red,gold)
Call point resistor value 470 to 680 Ω, 0.5 or 1 watt
Number of general circuits 2
Outputs fused AT 600mA
Maximum number of bells @ 50mA of each Sounder output 12
Battery fuse 1.85A resettable fuse
Sounder outputs 400mA F 20mm
Output type NC and NO relay
Maximum current 100mA
Largest acceptable conductor size 2.5mm2
Smallest acceptable conductor size 0.75mm2
Dimensions(mm) 320X231X90
Weight (with batteries) 7kg

Comparison Asenware  Zone Fire Alarm Control Panel

ITEM 1Zone panel 2Zone panel 4-16 Zone panel 4-32 Zone panel
Model No. AW-CFP2166-01 AW-CFP2166-02 AW-CFP2166-04-16 AW-CFP2166-04-32
Power specification
Mains supply voltage 110VAC or 240VAC
Internal power supply 27.2VDC
Total output current limited 500mA @ 240VAC 500mA @ 240VAC 3A @ 240VAC 3A @ 240VAC

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Asenware 2 Zone Fire Alarm Control Panel”

There are no reviews yet.

Need Help? Chat with us

Select at least 2 products
to compare